Renewable Technologies
The evaluation of technologies focused on the performance comparison of two solar PV systems and two wind turbines
Study Outcomes
It was concluded that all technologies were viable. However, it was recommended that a 50 kW Endurance turbine was used with a payback time of 6.4 years. Solar PV 49.35 kWp was also Recommended with a payback time of 9.6 years.
Renewable Technologies |
Carbon emissions saved |
FIT Income | Electricity Generated kWh |
50 kW Wind turbine | 70.3 tonnes | £34,408 | 136,000 kWh |
Solar PV 49.35 kWp | 17.9 tonnes | £11,361.36 | 34,533 kWh |